Overview
A curtain wall carries no floor loads; it transfers wind and self-weight to the structure through brackets. Unitized systems are pre-assembled in the shop into modules, reducing work at height.
Performance (wind load, water tightness, air permeability, inter-storey drift) is proven by mock-up tests to EN 13830, AAMA 501 or ASTM. Low-E insulated glass cuts solar gain and supports green building certification.
Uses
- 01Office and factory admin façades
- 02Towers and hotels
- 03Showrooms and malls
- 04Lobbies and atria
Selection and acceptance checks
- Check mock-up test reports (wind, water, air)
- Check brackets, anchors and movement joints
- Site water spray tests at the specified rate
Reference standards
- EN 13830
- AAMA 501
- ASTM E330
- ASTM E331
For reference only. The standards for each project follow its design documents, current Vietnamese codes and the investor’s requirements.
Sectors and solutions
Sectors
Commercial buildings High-rise buildings FDI factories